DIT-513 / DIT-515 Infrared Thermometer with Laser Mark Product ID: DIT-513 / DIT-515

Infrared Thermometer
Features Model: DIT-513
1.CE-Mark approval
2.Portability and simplicity one-hand operation
3.Display Back-Light feature
4.Auto DATA HOLD function after releasing MEASURE Button
5. °C/ °F user-selective
6. Fixed emissivity (e) 0.95 for most substances
7. Auto power off function
8. Use thermopile detection sensor (6-14 micro m)
9. Attached PVC cover

Infrared thermometer Model: DIT-515
Features:
1. CE-Mark approval
2. Portability and simplicity one-hand operation
3. Display Back-Light feature
4. Auto DATA HOLD function after releasing MEASURE Button
5. °C/ °F user-selective
6. With MAX, MIN record function
7. With SET, Hi, Lo limits beeper function
8. Adjustable emissivity (e) 0.1 to 1.00
9. Auto power off function
10.Use thermopile detection sensor (6-14 micro m)
11.Attached PVC cover

Certificate:CE
  • Infrared Thermometer DIT 513 Specifications:
    • Display: 3 1/2 digit liquid crystal display (LCD) with a
    • maximum reading of 1999.
    • Low battery indication: The "" "" is displayed when the
    • battery voltage drops below the operating level.
    • Operating environment: 0°C to 50°C atStorage environment: -20°C to 60°C, 0 to 80% R.H.
    • with battery removed from meter.
    • Accuracy: Stated accuracy at 23°C±5°C,Auto power off: 10 seconds.
    • Dimensions: 148mm(H) x 105mm(W) x 42mm(D).
  • DIT 513 Infrared Thermometer Specification:
    • Temperature:
    • Sensor: Thermopile (6-14 micro m)
    • Range: -30 °C to 550 °C, -22 °F to 1022 °F
    • Resolution: 0.1/1 °C (auto), 1°F
    • Response Time: 0.25 second
    • Accuracy:
    • +/-(2 C/4 °F) on -30 C to 100 C (-22 °F to 212 °F)
    • +/-(2% reading) on 101 °C to 550 °C (213°F to 1022 °F)
    • Fixed emissivity (e): 0.95
    • Field of View: 100mmØ at 1000mm
    • Laser Specifications:
    • Laser safety classification of Class 2
    • Wave Length: Red (630-670nm)
    • Power out:
    • DIT 515 Infrared Thermometer Specifications:
      • Specifications:
      • Display: 3 1/2 digit liquid crystal display (LCD) with a
      • maximum reading of 1999.
      • Low battery indication: The "" "" is displayed when the
      • battery voltage drops below the operating level.
      • Operating environment: 0 C to 50 C atStorage environment: -20 C to 60 C, 0 to 80% R.H.
      • with battery removed from meter.
      • Accuracy: Stated accuracy at 23°C±5°C,Auto power off: 10 seconds.
      • Dimensions: 148mm(H) x 105mm(W) x 42mm(D).
    • DIT 515 Infrared Thermometer
      • Temperature:
      • Sensor: Thermopile (6-14 micro m)
      • Range: -30°C to 550 °C, -22 °F to 1022°F
      • Resolution: 0.5/1 °C (auto), 1°F
      • Response Time: 0.25 second
      • Accuracy:
      • +/-(2 °C/4 °F) on -30 °C to 100 °C (-22 °F to 212 °F)
      • +/- (2% reading) on 101 °C to 550°C (213 °F to 1022°F)
      • Adjustable emissivity (e): 0.1 to 1.00
      • Field of View: 100mm Oslash; at 1000mm
      • Laser Specifications:
      • Laser safety classification of Class 2
      • Wave Length: Red (630-670 um)
    • Infrared Thermometer Applications:
      • 1.Measure surface temperature of objects which are
      • difficult to reach or unsafe to contact
      • 2.Measure hot spots in electrical panels and equipment
      • 3.In-process temperature measurements
    • Comparison between DIT 513/ DIT 515 Infrared Thermometer
      • 1. Emissivity(e) : DIT513 : 0.95 Fixed ; DIT 515 : Adjustable 0.1 to 1.0
      • 2. Set Max/Min, Hi/Lo, Beeper for DIT 515 only.
      • Resolution: DIT-513  0.1  °C ; DIT-515 0.5  °C

 A non-contact infrared thermometer is  useful tool for measuring temperature under circumstances where  contact  thermocouples or probes sensors cannot be used or do not procure  accurate measruing data for a variety of reasons.