CA-600 AC/DC Current Transducer /Transmitter Product ID: CA-600,

DC Current Range: 0-1000A±(1.5~3.5%+3A)

AC Current Range: 0-1000A±(1.5~3.5%+3A)

Output: 0-1V rms or DC with>=1MΩ input impedance

Transfer Rate: 1mV/1A

Overload Protection: 1200A for 60 seconds maximum.
-----------------------------------------------------------------------
General

Jaws Opening Capability: 57mm Conductor, 70 x 18 mm bus bars

Power Requirement: One 9V battery

Dimensions: 9.6"x3.9"x1.6" (244x100x40mm)

Cable length :
The length of the cable is curled wire 2.63 Feet (80 cm ) and extension is able to be 4.3 Feet ( 130 cm ) approx.

Certificate:CE
  • CA600
    • DC/AC Current Clamp Adapter
    • Model:CA-600
    • Features :
    • Coverts any DMM to a current clamp
    • Measure current without disconnecting circuit under test
    • AC/DC 600A capability
    • Dual Hall-effect sensors
    • Accuracy DC:±2%+2A AC: ±3%+2A (50~400Hz)
    • For use with any multi-meter at 200mV or 2V ranges for direct readout.
    • Input impedance at least 1MΩ
    • Power on indicating
    • Zero adjustment knob to compensate the hysteresis effect in
    • DC Measurements.)
    • Transformer ratio:1000:1
    • Output 1mV/A
    • Jaw opening capability:30mm conductor
    • Confirm to Safety:IEC 1010-1, IEC 1010-2-032,UL,CE approved.
    • Low battery indication Model : CA 600
  • CA600
    • Specifications :
    • Measurement range:
    • 600A DC or AC
    • Accuracy:
    • ±(2% reading +2A)
    • Frequency Response (AC):
    • 50Hz to 400Hz
    • Input Resistance:
    • 10kHz typical
    • Maximum Conductor Size:
    • 1.1"" (30mm)
    • General:
    • Power Requirement:
    • 9V battery
    • Dimensions
    • 7x2.75x1.3(178x70x33mm)
    • Weight:
    • 11 oz. (290g)
    • Accessories:
    • Battery, owners man
  • CA1000D FEATURES:
    • 1000Amp AC/DC Clamp Adapter  
    • Model:CA-1000D
    • Features :
    • 1000A AC or DC Current Clamp
    • Measure current without disconnecting circuit under test
    • Measure to 1000A DC or AC
    • Outputs 1mV per Amp, operates on 2V range of any DMM
  • CA1000D SPECIFICATIONS:
    • Model : CA-1000D
    • Click here for larger image
    • Specifications :
    • DC Current Range:
    • 0-1000A±(1.5~3.5%+3A)
    • AC Current Range:
    • 0-1000A±(1.5~3.5%+3A)
    • Output
    • 0-1V rms or DC with>=1MΩ input impedance
    • Transfer Rate:
    • 1mV/1A
    • Overload Protection
    • 1200A for 60 seconds maximum.
    • General
    • Jaws Opening Capability:
    • 57mm Conductor, 70 x 18 mm bus bars
    • Power Requirement:
    • One 9V battery
    • Dimensions:
    • 9.6""x3.9""x1.6"" (244x100x40mm)
    •  
    • --------------------------------------------------------------------------------
    • TECPEL CO., LTD
    • NO, 13, ALLEY 5, LANE 31 CHUNG-TEH STREET,
    • TAIPEI 110, TAIWAN, R.O.C.
    • E-MAIL: sales@tecpel.com Web-site: http://www.tecpel.com
    • TEL:2-27375866 FAX:886-2-
  • CA-06 (Option)
    • BNC- Female 4mm Banana post adapter for receiving Signal output from CA-60 and able to be monitored by oscilloscope.