Analog High Voltage Meter(Tecpel HVP-40M) Product ID: Tecpel HVP-40M

Analog High Voltage Test Probe test mete
 
HVP-40M Features:
DC 40KV CAT II Pollution 2
600M Ohm Impedance
25KV ± 2%, 40KV ± 3%
T.C. 200 ppm/°C.
Positive Polarity only.
Resolution 1KV
No Need power.
CE,   IEC1010

Category: Electric Testers
Certificate:CE
  • HVP-40M
    • SPECIFICATIONS ( 20 ± 5°C, RH < 80% )
    • ! WARNING !
    • Before taking any measurements, first connect the alligator clip of this probe to earth ground and make sure connection is electrically good.
    • Input impedance:600M Ohm
    • Maximum operation voltage:40KV DC , CAT II , Pollution 2
    • Polarity:Positive only
    • Display:Analog indicate
    • Accuracy:Factory calibrater 25KV ± 2%
    • FULL scale 40KV ± 3 %
    • Temperature Coefficient:Maximum loading Current:Maximum loading power:Voltage Range:40KV / 1 Range
    • Voltage resolution:1KV
    • Power source:Need not power
    • Operating temperature:0 °C ~ + 50 °C.
    • Storage temperature:- 20 °C ~ + 70 °C.
    • Ground lead length:90cm ( 35 "" )
    • Dimensions:420 L x 80 ø
    • Weight:360g