TandD TR-74Ui Accumulating Light, Humidity and Temperature Data Logger(Tecpel TR-74Ui) Product ID: Tecpel TR-74Ui

 


Overview





Product Type


Measurement Items





The ""TR-74Ui Illuminance UV Recorder"" is a data logger designed to simultaneously measure and record four items: Illuminance, Ultraviolet Light (UV), Temperature and Humidity. In addition to these, the TR-74Ui is also capable of displaying Cumulative Illuminance and Cumulative Amount of Ultraviolet Light in the LCD display. From dim moonlight to the summer sun, Illuminance can be measured within a wide range.

The product is an all-in-one package that includes the data logger unit, sensors and software. We offer two types of packages with different temperature/humidity sensors depending on your required measurement range and accuracy needs.
Simply by connecting to a PC via a USB connection and carrying out a few easy steps, the measurement and recording of data can be started.

Not only can recorded data be easily downloaded to a PC via USB communication, but it can also be collected from data loggers via infrared communication to our T&D Data Collector TR-57DCi (sold separately). The TR-57DCi enables the user to gather and check recorded data on the spot without having to manually gather the data loggers.



 

Application Examples


* In art museums and other exhibit forums to manage illuminosity and help prevent deterioration of exhibits
* Management during all aspects of plant and food production
* For use in the development, testing, manufacture and sales of products for cutting UV rays
* UV reduction management in schools from kindergartens to universities
* For home and office use in the management or illuminosity and UV rays
* Design and management of homes and architectural buildings
* For managing the reduction of UV rays at swimming pools, the ocean, mountains and in parks
* For management and adjustment of illuminosity for photography and film
* For management in the production, storage and sales of foodstuffs and beverages
* For use at supermarkets, convenience stores and drugstores in UV product sales promotion materials





  • Measure and Record Illuminance, Ultraviolet Light (UV), Temperature and Humidity

  • Temperature/Humidity Sensor Selection

  • View Cumulative Illuminance and Cumulative Amount of Ultraviolet Light in LCD Display

  • Measure Illuminance within Wide Range

  • View and record Illuminance in Resolutions to 0.01 lx

  • Simultaneously View Four Measurement in One Easy-to-Read Graph

  • Large Logging Capacity: 8,000 Data Sets

  • Transmit Recorded Data to PC via USB Connection



Measure and Record Illuminance, Ultraviolet Light (UV), Temperature and Humidity

TR-74Ui Illuminance UV Recorder is a data logger designed to simultaneously measure and record four items: Illuminance, Ultraviolet Light (UV), Temperature and Humidity. This versatile data logger can be applied in a wide range of applications, from business to personal use.

 

Temperature/Humidity Sensor Selection

The TR-74Ui standard package includes our THA-3151 Temperature/Humidity Sensor and the TR-74Ui-H high precision package includes our HHA-3151 Temperature/Humidity Sensor.

 

View Cumulative Illuminance and Cumulative Amount of Ultraviolet Light in LCD Display

In addition to Illuminance, Ultraviolet Light (UV), Temperature and Humidity, the TR-74Ui is also capable of displaying Cumulative Illuminance and Cumulative Amount of Ultraviolet Light in the LCD display.

Cumulative Illuminance Display Range: 0 to 90,000,000 lxh
Cumulative Amount of Ultraviolet Light Display Range: 0 to 62W/cm2h

 

Measure Illuminance within Wide Range

From dim moonlight to the summer sun, Illuminance can be measured within a wide range.

Illuminance Measurement Range: 0 to 130,000 lx

 

View and record Illuminance in Resolutions to 0.01 lx

High resolutions of up to 0.01 lx make it possible to measure even under less light conditions.

 

Simultaneously View Four Measurement in One Easy-to-Read Graph

The recorded data downloaded from TR-74Ui Units is read by the Multi-scale Graph and the data of four items, Illuminance, Ultraviolet Light (UV), Temperature and Humidity, can be simultaneously viewed in graph or tabular form as well as printed or output.

 

Large Logging Capacity: 8,000 Data Sets

The TR-74Ui Illuminance UV Recorder can measure and record up to 8,000 data sets. (One data set consists of readings for all channels: Illuminance, Ultraviolet Light, Temperature and Humidity.)
At the longest recording interval of 60 minutes, a Unit can record one year's worth of measurements.

* The battery life for a TR-74Ui Unit is about 6 months. In order to record measurements consecutively for 1 year, the battery should be periodically changed.
Battery life varies depending upon the type of battery, the battery performance, the measuring environment, and the frequency of communication.

 

Transmit Recorded Data to PC via USB Connection

It is possible to connect a TR-74Ui Unit directly to your computer with a USB cable.
If the computer has more than one USB port, it is possible to connect multiple TR-74Ui Units to one computer at the same time.

Connecting more than one TR-74Ui Unit at a time can only be done if using Windows 7 and Windows Vista.


Moreover, it is possible to gather current readings from the TR-74Ui connected to your computer and view those readings in the computer display.


 




Category: Data Loggers
Certificate:CE
Specifications
ProductTR-74UiTR-74Ui-H
Temperature/Humidity Sensor (External) THA-3151 HHA-3151(High-Precision Type)
Thermistor Polymer Resistance Platinum Resistance Electrostatic Capacitance
Measurement Channels Temperature 1ch Humidity 1ch Temperature 1ch Humidity 1ch
Units of Measurement °C, °F %RH °C, °F %RH
Measurement Range 0 to 55 °C 10 to 95 %RH -30 to 80 °C 0 to 99 %RH
Accuracy ±0.5 °C ±5 %RH (at 25 °C, 50 %RH) ±0.3°C (at 10 to 40 °C)±0.5°C (at all other temperatures) ±2.5 %RH(at 25 °C, 10 to 85 %RH) ±4.0 %RH(at 25 °C, 0 to 10 % or 85 to 99 %RH) At temperatures other than 25 °C and ≥ 0 °C, add ±0.1 %RH per degree of difference from 25. Humidity Hysteresis: ±1.5 %RH or lower(*1)
Measurement Resolution 0.1 °C 1 %RH 0.1 °C 0.1 %RH
Response Time (90%) Approx. 7 min. Approx. 7 min. Approx. 20 sec.
 
Illuminance/UV Sensor (External) ISA-3151
Measurement Channels Illuminance: 1ch
UV intensity: 1ch
Units of Measurement Illuminance: lx, Klx
UV intensity: mW/cm2
Measurement Range Illuminance: 0 lx to 130 Klx
UV Intensity: 0 to 30 mW/cm2
Units of Cumulative Measurement Cumulative Illuminance: lxh, Klxh, Mlxh
Cumulative amount of UV Light: mW/cm2, W/cm2
Display Range of Cumulative
Measurement
Illuminance: 0 lxh to 90 Mlxh
UV Intensity: 0 mW to 62 W/cm2h
Accuracy Illuminance: 10 lx to 100 Klx:±5 % (at 25°C, 50 %RH) UV Intensity: 0.1 to 30 mW/cm2:±5 % (at 25°C, 50 %RH) (*2)
Relative Spectral Response Illuminance: Approximated to the CIE standard response function V (λ )
UV Intensity: 260 to 400 nm
Measurement Resolution Illuminance: Minimum of 0.01 lx
UV Intensity: Minimum of 0.001 mW/cm2
Response Time (90%) 3 sec. (at recording interval of 1 sec.)
6 sec. (at other intervals)
 
Logging Capacity 8,000 data sets (One data set consists of readings for all channels in that type of unit.)
Recording Interval Select from 15 choices: 1, 2, 5, 10, 15, 20, 30 sec. or 1, 2, 5, 10, 15, 20, 30, 60 min.
Recording Mode (*3) Endless (Overwrite oldest data when capacity is full) or One Time (Stop recording when capacity is full)
LCD Display Items Measurements, Battery Life Warning, etc.
- Measurements: Illuminance / UV Intensity / Temperature / Humidity / Cumulative Illuminance / Cumulative amount of UV Light
- Display Pattern: Alternating or Fixed display
- Display Digits: Up to 4 digits
Communication Interfaces USB Communication, Serial Communication (RS-232C) (*4), Infrared Communication (IrPHY 1.2 low power)
Communication Time Downloading time for one unit at full capacity
- Via USB communication: approx. 45 sec.
- Via infrared communication: approx. 60 to 80 sec.
Power AA Alkaline Battery (LR6) x 1
Battery Life (*5) Approx. 6 months
Dimensions H 55 mm x W 78 mm x D 18 mm
Weight About 62 g (including battery, excluding sensor)
Operating Environment Temperature: -10 to 60 °C Humidity: 90 %RH or less (no condensation)
Accessories AA alkaline battery (LR6), USB Communication Cable (US-15C), Illuminance/UV Sensor (ISA-3151), Temperature/Humidity Sensor (THA-3151 or HHA-3151), Software (CD-ROM), User's Manual Set (Warranty Included)
  • *1) When used in environments where temperature and humidity are over the values of 50°C 75%, 60°C 50%, 70°C 35%, and 80°C 25%, sensor hysteresis may fluctuate by values greater than ±1.5%RH. Under certain circumstances, it may take some time to return to normal measurement capability.
  • *2) Compared to the value measured by the T&D standard sensor for calibration under our calibration light source.
  • *3) Only ""Endless"" is available when using RTR-500W for Windows.
  • *4) If necessary, serial communication can be established by using our communication protocol (contact your local distributor) to write a software program. In such a case, an optional serial communication cable (TR-07C) is needed.
  • *5) Battery life varies depending upon the ambient temperature in which it is used, the recording interval, the frequency of communication, and the battery performance. All estimates are based on operations carried out with a new battery and are in no way a guarantee of actual battery life. When infrared communication function is enabled, battery life may be shortened if the unit is used under the inverter type fluorescent lighting.
Dimensions
TR-74Ui
1: Sensor Jack
2: POWER Button
3: LCD Display
4: DISPLAY Button
5: INTERVAL Button
6: REC/STOP Button
7: USB Communication Cable Jack
8: Illuminance Light Receiving Area (Materials: Polycarbonate)
9: Ultraviolet Light Receiving Area (Materials: Glass)
10: Temperature/Humidity Sensor Area
 
 
Standard Kit
  • Manual
  • Battery
  • Cable
  • Illumimance UV Sensor (ISA-3151)
  • Temperature/Humidity Sensor (THA-3151/HHA-3151)
  • CD-ROM
Setup
Optional Sensor for TR-74Ui
ISA-3151 (Illuminance UV Sensor)
 ISA-3151
Measurement Items Illuminance UV Intensity
Measurement Range 0 to 130,000lx 0 to 30mW/cm2
Measurement Resolution Minimum: 0.01 lx Minimum: 0.001 mW/cm2:
Measuring Accuracy 10 to 100,000 lx:
±5%(*1)
(at 25°C and 50%RH)
0.1 to 30 mW/cm2
±5%(*1)
(at 25°C and 50%RH)
Relative Spectral
Response
(*2) 260 to 400 nm
Cosine Correction
(cosΘ)
(*3) -
Operating
Environment
Temperature: -10 to 60°C
Humidity: 90%RH or less
(no condensation)
Conditions for Use Do not expose to condensation, dampness, corrosive gases or organic solvents
Sensor Dimensions H23 x W65 x D12.6 mm
Cable Length 1.5 m

*1) Compared to the value measured by the T&D standard sensor for calibration under our calibration light source.
*2) Approximated to the CIE standard response function V (λ).
*3) Within ±1.5% at 10°; Within ±3% at 30°; Within ±10% at 60°; Within ±30% at 80°
Materials:
(1) Polycarbonate
(2) Glass
(3) Vinyl chloride-shielded wire
Unit: mm
THA-3151 (Temperature/Humidity Sensor)
 THA-3151
Measurement Items Temperature Humidity
Measurement Range 0 to 55°C 10 to 95%RH
Measurement Resolution 0.1°C 1%RH
Measuring Accuracy Avg. ±0.3°C ±5%
(at 25°C and 50%RH)
Sensor Response
Time
About 7 min. (90%)
Humidity Hysteresis - ±1%RH (30 to 90%RH)
Operating
Environment
Temperature: 0 to 55°C
Humidity: 95%RH or less
(no condensation)
Conditions for Use Do not expose to condensation, dampness, corrosive gases or organic solvents
Sensor Dimensions H18 x W51.5 x D10 mm
Cable Length 1.5 m

Materials:
(1) Polycarbonate
(2) Vinyl chloride-shielded wire
Unit: mm
HHA-3151 (Temperature/Humidity Sensor-High-Precision Type)
Measurement Items Temperature Humidity
Measurement Range -30 to 80°C 0 to 99%RH
Measurement Resolution 0.1°C 0.1 %RH
Measurement Accuracy ±0.3°C (at 10 to 40 °C)±0.5°C (at all other temperatures) ±2.5 %RH(at 25 °C, 10 to 85 %RH) ±4.0 %RH(at 25 °C, 0 to 10 % or 85 to 99 %RH) At temperatures other than 25 °C and ≥ 0 °C, add ±0.1 %RH per degree of difference from 25.
Response Time (90%) Approx. 7 min. Approx. 20 sec.
Sensor Temperature Durability -30 to 80°C
Long Term Stability ±1%RH/yr, ±0.1°C/yr
Humidity Hysteresis - 1.5%RH or lower (*1)
Sensor Dimensions H 19 mm x W 65 mm x D 10 mm
Cable Length 1.5 m
Conditions for Use Do not expose to condensation, dampness, corrosive gases or organic solvents
*1: When used at temperatures equal to or higher than 0°C.


Materials: ①Polycarbonate ②Vinyl chloride-shielded wire
Unit: mm
 
Options for TR-74Ui
TR-1C30
Sensor Extension Cable
Cable Length: 3 m

1. Vinyl chloride-shielded wire

NOTE: Up to 3 extension cables can be connected to one sensor (Temperature/Humidity Sensor THA-3151 / HHA-3151, Illuminance UV Sensor ISA-3151).
Unit: mm
TR-07K2
Wall Attachment
Included:
Screw x 2
Double-sided Tape x 1
Unit: mm
US-15C
USB Communication Cable
Cable Length: 1.5 m
Unit: mm