GOS-6112 / GOS-6103 / GOS-6103C 100MHz Oscilloscope Product ID: GOS-6112 / GOS-6103 / GOS-6103C

The GOS-6100 Series is a 100MHz, two-channel, dual-sweep, portable oscilloscope for general purpose
use. A microprocessor-based operating system controls most of the functions of the instrument, in
cluding cursor readout and digitized panel setting.
On-screen alphanumeric readout and cursor function for voltage, time, frequency and phase
measurement provide extraordinary operational convenience. The advance Time Base Auto-rang fun
ction conveniently acquires waveforms at the push of button (GOS-6103/ 6103C). Ten different user
defined instrument settings (GOS-6103/ 6103C) can be saved and recalled without restriction.
The vertical deflection system has two input channels. Each channel has 11 basic deflection factors
from 2mV to 5V per division. The horizontal deflection system provides single, dual or delayed sweeps
from 0.5s to 50ns per division (delayed sweep, 50ms to 50ns per division). The trigger system provides
stable triggering over the full bandwidth of the vertical deflection system.

Category: Oscillosocpes
Certificate:CE (Except GOS-6103C)
 
  • SPECIFICATIONS
    • CRT
    • Type 6-inch rectangular type with internal graticule; 0%, 10%, 90% and 100% markers. 8 x 10 DIV (1 DIV=1 cm)
    • Phosphor P31
    • Accelerating Potential 16 kV approx.(GOS-6103/GOS-6103C), 12kV approx.(GOS-6112)
    • Illumination Continuously adjustable (GOS-6103/GOS-6103C)
    • Z-axis input Coupling : DC
    • Sensitivity : 5V or more
    • Maximum input voltage : 30V(DC+AC peak) at 1kHz or less
    • Bandwidth : DC ~ 5MHz
    • --------------------------------------------------------------------------------
    • VERTICAL SYSTEM:
    • Sensitivity 2mV ~ 5V / DIV,11 step in 1-2-5 sequence
    • Sensitivity Accuracy < 3% (5 DIV at the center of display)
    • Vernier Vertical Sensitivity Continuously variable to 1 / 2.5 or less panel-indicate value
    • Bandwidth(-3dB) DC ~ 100MHz (2mV/DIV : DC ~ 20MHz)
    • Rise Time 3.5nS (2mV/DIV : 17.5 nS)
    • Signal Delay Leading edge can be monitored
    • Max. Input Voltage 400V (DC+AC peak) at 1kHz or less
    • Input Coupling AC, DC, GND
    • Input Impedance 1MΩ+2%// approx. 25pF
    • Vertical Mode CH1, CH2, DUAL (CHOP/ALT), ADD, CH2 INV.
    • Bandwidth Limited 20MHz
    • Common-Mode Rejection Ratio 50 :1 or better at 50kHz
    • Dynamic Range 8 div at 60MHz;5 div at 100MHz (GOS-6112)
    • 8 div at 100MHz (GOS-6103/GOS-6103C)
    • --------------------------------------------------------------------------------
    • HORIZONTAL SYSTEM:
    • Horizontal Modes MAIN (A), ALT, DELAY (B)
    • A(main)Sweep Time 50nS ~ 0.5S / DIV, continuously variable (UNCAL)
    • B(delay)Sweep Time 50nS ~ 50mS / DIV
    • Accuracy + 3% (+ 5% at x 10 MAG)
    • Sweep Magnification x 10 (maximum sweep time 5nS / DIV)
    • Hold Off Time Variable
    • Delay Time 1µS ~ 5S
    • Delay Jitter Better than 1:20000
    • Alternate Separation Variable
    • --------------------------------------------------------------------------------
    • TRIGGER:
    • Trigger Modes AUTO, NORM, TV
    • Trigger Source CH1, CH2, LINE, EXT
    • Trigger Coupling AC, DC, HFR, LFR
    • Trigger Slope ""+"" or ""-"" polarity or TV sync polarity
    • Trigger Sensitivity Mode
    • Frequency
    • INT
    • EXT
    • AUTO
    • 10Hz~20MHz
    • 0.35 DIV 50 mV
    • 20MHz~100MHz
    • 1.5 DIV 150 mV
    • NORM
    • DC~20MHz
    • 0.35 DIV
    • 50 mV
    • 20MHz~100MHz
    • 1.5 DIV
    • 150 mV
    • TV
    • sync signal
    • 1 DIV
    • 200 mVpp
    • TV Sync TV-V, TV-H
    • Max. External Input Voltage 400V (DC+AC peak) at 1kHz
    • External Input Impedance 1MΩ + 5%, // approx. 25pF
    • --------------------------------------------------------------------------------
    • X-Y OPERATION:
    • Mode X-axis :selectable CH1, CH2, EXT
    • Y-axis :selectable CH1, CH2, CH1 and CH2
    • Sensitivity Accuracy 2mV ~ 5V/DIV+3%; EXT : 0.1V/DIV+ 5%
    • X-axis Bandwidth DC ~ 500kHz (-3dB)
    • Phase Error 3º or less from DC ~ 50kHz
    • --------------------------------------------------------------------------------
    • OUTPUT SIGNAL:
    • Trigger Signal Output Voltage : approx. 25mV/DIV into 50Ω
    • Frequency response : DC ~ 10MHz
    • Calibrator Output 1kHz Squarewave, 2Vpp+2%
    • --------------------------------------------------------------------------------
    • CURSOR READOUT FUNCTION:
    • Cursor Measurement Function ΔV,ΔV%,ΔVdB,ΔT,1/ΔT,ΔT%,Δθ
    • Cursor Resolution 1 / 100 DIV
    • Effective Cursor Range Vertical : + 3DIV ; Horizontal : + 4DIV
    • Panel Setting Display Vertical : V/DIV(CH1,CH2), UNCAL, ALT/CHOP/ADD, INV, probe factor, AC/DC/GND
    • Horizontal : S / DIV(MTB,DTB), UNCAL, x 10MAG, delay time, HO
    • Trigger : source, coupling, slope, level, TV-V, TV-H
    • Others : X-Y, lock, save/recall MEM 0-9(GOS-6103/GOS-6103C)
    • --------------------------------------------------------------------------------
    • AUTO MEASUREMENT FUNCTION (GOS-6103C):
    • Parameter Function FREQ, PERIOD, +WIDTH, +DUTY ( + or - polarity selected by trigger slope)
    • Display Digits Max. 6-digits, decimal
    • Frequency Range 50Hz ~ 100MHz
    • Accuracy 1kHz ~ 100MHz : +0.01%;50Hz ~ 1kHz : +0.05%
    • Measuring Sensitivity >2 div (Measuring source selected from CH1 and CH2 as synchronous signal sources)
    • --------------------------------------------------------------------------------
    • SPECIAL FUNCTION:
    • TIME/DIV Auto Range Provided (GOS-6103/GOS-6103C)
    • Panel Setting Save & Recall 10 sets (GOS-6103/GOS-6103C)
    • Panel Setups Lock Provided
    • --------------------------------------------------------------------------------
    • POWER SOURCE AC 100V / 120V / 230V + 10%, 50 / 60Hz
    • --------------------------------------------------------------------------------
    • ACCESSORIES :
    • Power cord x1,
    • Instruction manual x1,
    • Probes(10:1/1:1)x2
    • --------------------------------------------------------------------------------
    • DIMENSIONS & WEIGHT 310(W) x 150(H) x 455(D) mm;Approx. 9kg C
GOS-6112/6103/6103C FEATURES
  • Cursor Readout Analog Oscilloscope
  • 100 MHz, Dual Channel, Delayed Sweep
  • Built-in 6 Digit Universal Counter (GOS-6103C)
  • 10 Sets Memory for Front Panel Setting Save & Recall (GOS-6103/GOS-6103C)
  • Time Base Auto-range (GOS-6103/GOS-6103C)
  • Cursor Readout with 7 Measurements
  • Panel Setup Lock of Digital-Control Functions
  • Buzzer Alarm
  • LED Indicators
  • TV Synchronization
  • Trigger Signal Output
  • Z-Axis Modulation Input
  • SMD Technology, High Stability and Reliability
  • ( GOS-6103C Without CE Approved.)