T and D Web Thermo Recorder(TR-71W_TR-72W) Product ID: TR-71W_TR-72W

T and D Web Thermo Recorder


Overview





Product Type


Measurement Items





Thermo Recorder TR-7W is a new type of Temperature & Humidity Data Logger that incorporates an Ethernet / LAN interface. This capability allows for quick and easy collection of recorded data and monitoring of current conditions; it can even send warning E-mails. These data loggers can be connected to either a wired or wireless LAN, allowing cost effective control of temperature and humidity from remote locations.

On Line demostration :http://web.trh.com.tw:8080/index.wcr




  • TR-71W




  • TR-72W



 

Application Examples


*Manage Temperature / Humidity in a warehouse remotely via the Internet.
*Manage Temperature / Humidity in a remotely located building.
*Collect Temperature / Humidity data in a factory via a LAN.
*Manage Temperature / Humidity by cell phone when away from home.

Category: Thermometers
Certificate:CE
  • Specification:
    • TR-71W TR-72W
    • Measurement Channel 2 Channel
    • (Select from Internal or External) 2 Channel
    • (Temperature and Humidity)
    • Measurement Item Temperature Only Temperature Humidity
    • External Sensor -40 to 110°C 0 to 50°C 10 to 95%RH
    • Optional Sensor -60 to 155°C *1 -40 to 110°C -
    • Measurement Accuracy
    • Average ±0.3°C(-20 to 80°C)
    • Average ±0.5°C(-40 to-20°C / 80 to 110°C) *2 ±5%RH
    • (At 25°C 50%RH)
    • Measurement Resolution Display 0.1°C 1%RH
    • Attached Sensors TR-0106 : TPE Resin-Shielded sensors x 2 TR-3110
    • Temp / Humidity Sensor x 1
    • Recording Interval 1,2,5,10,15,20,30Seconds,1,2,5,10,15,20,30,60Minutes / Total of 15 choices
    • Recording Capacity 8,000 Readings x 2 Channels
    • Recording Method Endless (Overwrite from the oldest data when recording capacity is full)
    • One time Method (Stop recording when recording capacity is full)
    • LCD Display Measurements (Ch1 only, Ch2 only, alternating display), Recording Status,
    • Battery Life Warning, Over-Measurement Range,
    • Amount of Recorded Data, Unit of Measurement
    • Power Source Special AC Adaptor ( DC5V )
    • Data Back-up *3 Saved for about 3 months with 1 lithium battery (CR-2032) *5
    • Interface Wired LAN:10 / 100 Base - TX RJ45 connector
    • Wireless LAN:IEEE802.11b CF type Wireless LAN Card *6
    • Dimentions *4 H55mm x W78mm x D39mm
    • Weight About 101g ( Including one battery )
    • Browser Functions View Temperature and Humidity Data in Graph Form , Start Recording,
    • Download Data , Monitor Current Readings , Check Back-up Battery
    • Warning Mail Function E-mail:Register up to 5 addresses to receive mail
    • Power Consumption About 290mA ( when using wired LAN )
    • Security Access Controlled IP Address , ID Password Authentication
    • Warking Environment for Main Unit Temperature : 0 to 50°C Humidity : 20 to 80%RH (without condensation) *7
    • Compatible OS Windows 2000 / XP
    • *1:1Compatible with all T&D tested and approved models.
    • *2:Errors in accuracy increase with increase in electrical noise.
    • *3:Battery Life varies according to type of battery, measuring environment , communication frequency , and ambient temperature. This estimate of battery life was based on normal use under normal conditions using a new battery. This is in no way a guarantee of battery life.
    • *4:Without protrusion.
    • *5:The backup battery is for data backup and emergency use only. The battery is not used under normal conditions. If using only the battery, network communication cannot occur.
    • *6:Please do not use any CF type Wireless LAN cards that have not been proven to be compatible. Please ask your local representative about which Wireless LAN cards can be used.
    • *7:Errors in accuracy increase with increase in electrical noise
  • See TR-72W operation via Internet
About the TR-7W Series Web Viewer
With the TR-7W Series Web Viewer you can not only use a browser to manage recording start and the downloading of recorded data, but can carry out various operations.

*For the browser please use Microsoft Internet Explorer 6.0 or higher.

Recording Settings
By setting the recording interval, the recording start time and the recording mode, recording will begin at the set date and time.
 
Downloading Recorded Data
It is possible to download recorded data from the TR-7W via a browser and create files.
 
Send Warning Messages by E-mail
Send E-mail warnings to up to 5 addresses when set temperature or humidity limits are exceeded.
 
View Readings on a Cell Phone
Current temperature and humidity readings can be viewed with a cell phone web browser.
 
Monitor Current Readings
The current readings measured every 30 seconds in the TR-7W can be displayed. It is also possible to view via a cell phone browser.
 
Graph
Measurements taken by the TR-7W loggers can be shown in graph form which updates every 5 minutes and can show up to 1 week's worth of data.
 
Main Unit Settings
Clock and Calendar Settings, Button settings, Channel Name Settings, Worning Mail Transmission Test, Forced Cancellation of Communication, Restarting the System.
Specifications
  TR-71WTR-72W
Measurement Channel 2 Ch (Select from Internal or External) 2 Ch (Temperature and Humidity)
Measurement Item Temperature Only Temperature Humidity
External Sensor -40 to 110°C 0 to 50°C 10 to 95%RH
Optional Sensor -60 to 155°C *1 -40 to 110°C -
Measurement Accuracy Average ±0.3°C(-20 to 80°C)
Average ±0.5°C(-40 to-20°C / 80 to 110°C)
±5%RH (At 25°C 50%RH)
Measurement Resolution Display 0.1°C 1%RH
Attached Sensors TR-0106 : TPE Resin-Shielded sensors x 2 TR-3110 : Temp / Humidity Sensor x 1
Recording Interval 1,2,5,10,15,20,30 sec./1,2,5,10,15,20,30,60 min./ Total of 15 choices
Logging Capacity 8,000 data sets (One data set consists of readings for all channels in that type of unit.)
Recording Method Endless (Overwrite from the oldest data when the capacity is full)
One time Method (Stop recording when the capacity is full)
LCD Display Measurements (Ch1 only, Ch2 only, alternating display), Recording Status,
Battery Life Warning, Amount of Recorded Data,Unit of Measurement
Power Source AC adaptor (AD-05C1 or AD-0605)
Data Back-up *3 Saved for about 3 months with 1 lithium battery (CR-2032) *5
Interface *6 Wired LAN:10 / 100 Base - TX RJ45 connector
Dimentions *4 H55mm x W78mm x D39mm
Weight About 101g ( Including one battery )
Browser Functions View Temperature and Humidity Data in Graph Form , Start Recording,Download Data , Monitor Current Readings , Check Back-up Battery
Warning Mail Function E-mail: Register up to 5 addresses to receive mail
Power Consumption About 290mA (when using wired LAN)
Security Access Controlled IP Address , ID Password Authentication
Operating Environment for Main Unit Temperature: 0 to 50°C / Humidity: 20 to 80%RH (without condensation) *7
Compatible OS Microsoft Windows 7 32/64bit English
Microsoft Windows Vista 32bit English
Microsoft Windows XP 32bit(SP2 or above) English
Microsoft Windows 2000 English
*1:1Compatible with all T&D tested and approved models.
*2:Errors in accuracy increase with increase in electrical noise.
*3:Battery Life varies according to type of battery, measuring environment , communication frequency , and ambient temperature. This estimate of battery life was based on normal use under normal conditions using a new battery. This is in no way a guarantee of battery life.
*4:Without protrusion.
*5:The backup battery is for data backup and emergency use only. The battery is not used under normal conditions. If using only the battery, network communication cannot occur.
*6:If you already have the following wireless LAN card, please use as directed. The wireless LAN card which has been tested and proven compatible with TR-71W/72W is the Dark Marketing Corporation's Wireless LAN card ""XI-815"". The production and sales of this card have been discontinued.
*7:Errors in accuracy increase with increase in electrical noise.
Dimensions
TR-71W
1.CF Interface Slot
2.Battery Case
3.Sensor Jack Channel :1
4.Sensor Jack Channel :2
5.DISPLAY Button
6.INTERVAL Button
7.REC/STOP Button
8.Reset Button 9.Ethernet Jack
10.Power Monitor LED
11.AC Adaptor Jack
12.Thermistor/TPE resin-shielded sensor
13.TPE resin-shielded wire
TR-72W
1.CF Interface Slot
2.Battery Case
3.Sensor Jack Channel :1
4.DISPLAY Button
5.INTERVAL Button
6.REC/STOP Button
7.Reset Button
8.Ethernet Jack
9.Power Monitor LED
10.AC Adaptor Jack
11.Temperature/Humidity sensor
12.Polypropylene resin