CL-325 Process Calibrator 4-20mA Product ID: CL-325

Features
1. 4-20mA (1K Ohm load, 24V Loop Supply)
2. 0-100.00mV,0-1.000V, 0-12.000V
3. K, J, E, T Thermocouple (°C and °F)
4. Frequency 1-62500 Hz
5. 0.025% Basic Accuracy
6. Easy Key-pad Operation
7. Easy Step and Auto Ramp Functions
8. 0-20mA, 0-24mA selectable
9. 0-100% Input (mA, mV, V )
10. Beeper warning when output is open (mA) or short (mV,V)

The model CL-327 is discontinued and replaced by CL-327A
process calibrator

Certificate:CE
  • Electrical Specification
    • Electrical Specification
    • (23°C ± 5°C, 3 minutes after power is on)
    • mA DC Current
    • (1K Ohm Max. Load, 24V Loop Supply)
    • Range Resolution Accuracy
    • 4 - 20mA, 0 - 20mA, 0 -24 mA 1µA ± 0.025% ± -3 µA
    • Beeper warning when output is open and specified current output > 1mA
    • mV, V DC Voltage (1mA Supply Current)
    • Range Resolution Accuracy
    • 0 - 100.00mV 10µV ± 0.05% ± 30µV
    • 0 - 10.000V 1mV ± 0.05% ± 3mV
    • 0 - 1.0000V 100µ V ± 0.05% ± 300µ V
    • Beeper warning when output is short and specified voltage output > 10mV
  • K, J, E, T type Thermocouples
    • K, J, E, T type Thermocouples
    • ( 1°C,1°F Resolution,1K Ohm load Min. )
    • Range Accuracy Range Accuracy
    • K: -200 to 0 °C ± 1.1°C K: -328 to 32°F ± 2.0°F
    • K: 0 to 1370 °C ± 0.8°C K: 32 to 2400°F ± 1.5°F
    • J: -100 to 0 °C ± 0.9°C J: -148 to 32°F ± 1.6°F
    • J: 0 to 760 °C ± 0.7°C J: 32 to 1400°F ± 1.2°F
    • E: -100 to 0 °C ± 0.9°C E: -148 to 32°F ± 1.6°F
    • E: 0 to 700 °C ± 0.7°C E: 32 to 1292°F ± 1.2°F
    • T: -200 to 0 °C ± 1.0°C T: -328 to 32°F ± 1.8°F
    • T: 0 to 400 °C ± 0.8°C T: 32 to 752°F ± 1.5°F
  • Frequency (1 - 62.5KHz, 1K Ohm Load Min.)
    • Frequency (1 - 62.5KHz, 1K Ohm Min.)
    • Range Resolution Accuracy
    • 1 - 125 Hz 1 Hz ± 0.04Hz
    • 126 - 62.5K 604 Selectable Frequencies
  • General Specification
    • General Specification Battery Type: 9V Alkaline Battery
    • Power Consumption: 60mA - 180mA (depends on output)
    • Low battery: 5.5V at 150mA Load
    • Display: 4 and 5 Digits
    • Operating Temperature: 0 to 50°C ( 32 to 122 °F)
    • Operating Humidity: Less than 85% relative
    • Storage Temperature: -20 to 60° C (-4 to 140 °F)
    • Storage Humidity: Less than 85% relative
    • Dimension: 88 x 168 x 26 mm
    • (3.46"" x 6.61"" x 1.03"")
    • Weight: 330 g / 11.63 oz
    • Accessories: Carrying case x 1
    • Users Manual x 1
    • K type thermocouple connector
    • External Battery Pack Holder
    • 1.5V AA Batteries x 6
    • Test leads with Alligator clip x 1
  • Q & A:
    • Is the output of the frequency function a sine or square or
    • triangular wave....?
    • It is square wave form and approx. 5V.